The DFW maintenance calendar
| Month | What to do | Why this month |
|---|---|---|
| March | Professional spring tune-up + replace filter | 90F days arrive in May. The units that fail in June were failing quietly in March. Tune-up now = 2-3 months of headroom to fix anything found at non-emergency prices |
| April | Filter + check drain line overflow pan | April rains + high humidity. Algae clogs condensate drains - the #1 cause of ceiling water damage in DFW attics |
| May | Filter + check thermostat batteries + test cooling performance on first 95F day | First real heat test of the season; catches a weak capacitor before it kills a compressor in June |
| June | Filter (monthly from now until October) | Compressor season begins. Filters cost $10-30; compressors cost $1,400-2,800 |
| July | Filter + clear 2 ft of debris/weeds from around the outdoor unit + gently rinse condenser coils with a garden hose (power OFF) | 100F-105F weeks. A dirty condenser coil raises head pressure and kills capacity exactly when you need it most |
| August | Filter + listen for the warning signs (see below) | Peak failure month in DFW. Emergency premium applies off-hours; catch it on a Tuesday |
| September | Filter + schedule fall heating check | First cold snap comes suddenly; furnaces that sat all summer have their own failure modes (cracked exchanger checks, ignition) |
| October | Professional heating tune-up + filter | Heating check covers heat exchanger integrity, gas pressure, ignition sequence, and CO safety - not just "does it blow warm" |
| November - February | Filter every 2-3 months + watch for heat-pump defrost behavior (normal) | Light season. Ideal window for duct sealing or insulation work at non-urgent prices |
The filter schedule that actually matters
- •1-inch filters: change every 30 days during cooling season (Jun-Oct), every 60-90 days otherwise. In a dusty DFW summer a loaded filter can cut airflow 10-15% in a single month.
- •4-inch media filters (Merv 8-11): every 3-6 months. If you do not know which you have, pull it and look - the size is printed on the frame.
- •Wrong filter = the expensive kind of cheap: upgrading to a Merv 13+ 1-inch filter without checking your blower capacity chokes airflow - the single most common self-inflicted AC problem we see.
What a real tune-up includes (so you can tell a real one from a 15-minute drive-by)
- •Measure capacitor microfarads against rated value (dies silently, takes the compressor with it)
- •Measure compressor and condenser-fan amp draw vs nameplate
- •Take manifold pressures: superheat and subcooling, not just "pressure looks OK"
- •Clean condenser coil (a garden-hose rinse between services helps; chemical clean once a year)
- •Clear/flush condensate drain + confirm float switch trips
- •Check contactor pitting and wiring for heat burn
- •Verify delta-T (supply vs return air temp) = 16-22F range in cooling
- •Check refrigerant charge against the manufacturer chart (not "top it off" - charging without finding the leak is a bandage)
- •Duct inspection: visible leaks, crushed flex, disconnected boots
If your tune-up receipt does not include measured numbers, it was not a tune-up.
The warning signs DFW homeowners should know cold
- •Runs constantly but house never reaches setpoint -> dirty coil, low charge, duct leak, or undersized unit. Do not ignore past 24 hours.
- •Icing on the copper line set in summer -> low charge or airflow restriction. Turn system OFF at the thermostat, fan ON, call. Running it iced can kill the compressor.
- •Water at the indoor unit or ceiling stain under it -> drain clog. Cut power, call. Attic units in DFW homes do real ceiling damage when pans overflow.
- •Breaker trips when outdoor unit starts -> hard-starting compressor or fan motor. Needs a meter, not a reset and forget.
- •Burning smell at first heat run of fall -> dust burn-off (normal, minutes) or something worse (call if it persists past 10-15 min).
The math on skipping maintenance
A $150 spring tune-up that finds a dying $220 capacitor prevents the $1,400-2,800 compressor it would have killed in June - at emergency premium - 3 months later, in a house with no cooling during the repair. The same logic applies to condensate drains (ceiling repairs start around $1,000) and coils (a chemical cleaning now vs a $1,200-2,800 evaporator coil replacement in 3 years). Maintenance does not prevent every failure - it prevents the cascade, which is what actually costs money.
What we recommend for North Texas homes
Twice-a-year professional service (spring cooling, fall heating) is the correct cadence in DFW - not an upsell. Between visits, filters monthly Jun-Oct, rinse the condenser once mid-summer, and keep 2 ft of clearance around the outdoor unit at all times. Ask about current maintenance plan pricing when you call: (214) 570-1540. Hours Mon-Fri 8:30-5:00, Sat 9:00-1:00; 24-hour emergency availability. TACL B21299E.
Schedule a Tune-Up - Call (214) 570-1540
Do not wait for the first 100°F day to find out your AC is not ready.